    专业自动化控制及成套控制设备生产厂家

    软启动器维修

    公司新闻

    0

    启功软起动器显示E103故障解决方法-软起动器维修

    故障显示:E103 ——软启动过热。系统在所有的工作状态中不断地检测晶闸管模块散热器的温度,一旦温度超标,可在3秒内实现对系统的保护,显示该信息。

    解决办法:检查负载是否过重或启动次数过于频繁。

    注:出现故障后,可按一下三种方式进行复位:

     按STOP键保持3秒钟

     短接外控端子RST与COM,并保持3秒钟

     软启动器断电后重新上电

  • 启功软起动器显示E103故障
  • 联系我们

    CONTACT US

    联系人:张经理

    手机:13389282290

    电话:029-81616045

    邮箱:426184036@qq.com

    地址:陕西自贸区西安国际港务区华南城